Phase number distinction
It can be divided into three-phase transformers and single-phase transformers. In three-phase power systems, three-phase transformers are generally used. When the capacity is too large and is limited by transportation conditions, three single-phase transformers can also be used in three-phase power systems to form a transformer group.
Winding distinction
It can be divided into two-winding transformers and three-winding transformers. Common transformers are two-winding transformers, that is, there are two windings on the iron core, one is the primary winding and the other is the secondary winding. Three-winding transformers are transformers with larger capacity (above 5600 kVA) and are used to connect three different voltage transmission lines. In special cases, Satons transformers with more windings are also used.
Structural classification
It can be divided into iron core transformers and iron shell transformers. If the winding is wrapped around the outside of the iron core, it is an iron core transformer; if the iron core is wrapped around the outside of the winding, it is an iron shell transformer. The two are just slightly different in structure, and there is no essential difference in principle. Power transformers are all iron core type.
The transformer is mainly composed of iron core, winding, oil tank, oil pillow, insulating bushing, tap changer and gas relay.
1. Iron core
The iron core is the magnetic circuit part of the transformer. Hysteresis loss and eddy current loss will generate heat during operation. In order to reduce heat loss and reduce volume and weight, the iron core is made of cold-rolled grain-oriented silicon steel sheets with high magnetic permeability less than 0.35mm. According to the arrangement of the winding in the iron core, there are iron core type and iron shell type.
In large-capacity transformers, in order to make the heat generated by the core loss be fully taken away by the insulating oil during circulation to achieve a good cooling effect, cooling oil channels are often provided in the iron core.
2. Winding
The winding and the iron core are the core components of the transformer. Since the winding itself has resistance or the joint has contact resistance, Joule's law shows that heat will be generated. Therefore, the winding cannot pass a current higher than the rated current for a long time. In addition, when the short-circuit current passes, a large electromagnetic force will be generated on the winding and damage the transformer. Its basic windings are concentric and overlapping.
The main faults of transformer windings are turn-to-turn short circuit and short circuit to the shell. Turn-to-turn short circuit is mainly caused by insulation aging, or due to transformer overload and mechanical damage to insulation during through short circuit. When the oil level in the transformer drops, causing the winding to be exposed to the oil surface, turn-to-turn short circuit can also occur; in addition, when there is a through short circuit, the winding is deformed due to overcurrent, causing mechanical damage to the insulation, which can also cause turn-to-turn short circuit. When the turn-to-turn short circuit occurs, the current in the short-circuited winding may exceed the rated value, but the current of the entire winding may not exceed the rated value. In this case, the gas protection is activated, and in serious cases, the differential protection device will also be activated. The reason for the short circuit to the shell is also due to insulation aging or oil moisture, oil level drop, or lightning and operating overvoltage. In addition, when a through short circuit occurs, the winding is deformed due to overcurrent, which can also cause a short circuit to the shell. When the shell is short-circuited, the gas protection device and the grounding protection are generally activated.
3. Oil tank
The body (winding and core) of the oil-immersed transformer is installed in an oil tank filled with transformer oil, which is welded with steel plates. The oil tank of medium and small transformers consists of a tank shell and a tank cover. The body of the transformer is placed in the tank shell. The body can be lifted out for maintenance by opening the tank cover.