50-2500kVA/35kV Oil Immersed Double Winding Transformer

50-2500kVA/35kV Oil Immersed Double Winding Transformer

S9

● High voltage side voltage: 6kV, 6.3kV, 10kV, 10.5kV, 11kV

● Low voltage Side voltage: 0.4kV

● Tapping Range:  ±2×2.5%, ±5%

● Transformer Vector Group: Yyn0 or Dyn11

● Tap Changer: NLTC or OLTC

● Certification: ISO9001, IEC60076, etc.

Note: More parameters can be customized according to customer requirements.

Payment & Shipping Terms

● Minimum Order Quantity: 1 piece

● Delivery Time: 10 to 20 days

● Packaging Details: wooden case

● Payment Terms: T/T, L/C, PayPal, Alipay/WeChat Pay, Visa

Product Overview

 

 

This 50–2500kVA/35kV oil‑immersed double‑winding transformer is purpose‑built as a high‑performance power distribution solution for high‑load, harsh operating scenarios, including industrial power systems, new energy power stations, and rail transit infrastructure. Engineered to endure sustained heavy‑duty operation and complex grid conditions, it delivers stable, continuous power output while directly solving the longstanding pain points of high energy waste, excessive operational noise, and insufficient reliability seen in conventional transformer products.
Core Advantages (With Data & Practical Value)

 

Top‑Tier Energy Efficiency & Cost Savings
Fully certified to GB 20052-2020 Level 1 energy efficiency standards, plus the internationally recognized IEC 60076 and ISO 45001 specifications, this unit leads the industry in low power consumption. Rigorous performance testing confirms its no‑load loss is reduced by 30% compared to traditional models. This dramatic drop in energy loss delivers tangible benefits: lower daily power consumption, substantial cuts in long‑term operational electricity costs, and a smaller carbon footprint for your facilities across the transformer's full service life.

 

Ultra‑Quiet Operational Performance
Through optimized structural design and high‑grade component matching, the transformer's operating noise is lowered by 4 decibels (dB) against standard alternatives. This improvement creates a quieter on-site working environment, making it especially well‑suited for noise‑sensitive applications such as urban rail transit and industrial zones near residential or commercial areas.

 

Superior Thermal Stability & Extended Service Life
It boasts exceptional thermal control, with its temperature rise index strictly limited to below K65. Precise temperature management slows insulation material aging, strengthens resistance to overloads and extreme working conditions, drastically improves long‑term running stability, and effectively prolongs the product's service life.

 

Technical Features
● Oil‑immersed cooling system: Delivers efficient heat dissipation to maintain stable performance under continuous high loads.
● Double‑winding structure: Ensures balanced power transmission, strong anti‑interference performance, and excellent compatibility with power grids.
● High‑grade magnetic core & optimized circuit design: Minimizes energy loss and maximizes energy conversion efficiency.
● Full standard compliance: Meets strict national and international safety, performance, and quality benchmarks for global application and reliable operation.
This oil‑immersed transformer fully fulfills your core demands for energy saving, consumption reduction, and high‑reliability power distribution, serving as the ideal choice for critical high‑load power scenarios.

 

Typical Application Scenarios

Thanks to its robust performance, high operational stability and excellent adaptability to heavy-duty working conditions, this 35kV oil-immersed transformer is widely applied in a diverse range of key power scenarios. It provides safe, efficient and continuous power supply support for industrial power systems, including large-scale manufacturing workshops, chemical plants and metallurgical facilities with intensive power consumption. It is also highly suitable for new energy power stations such as wind farms and photovoltaic power generation bases, matching the grid-connection and power distribution requirements of clean energy projects. In addition, its low-noise and high-reliability advantages make it an ideal power distribution equipment for rail transit infrastructure, ensuring stable and reliable operation of urban railways, light rails and other transportation power systems.

 

 

Type And Meaning

 

 

1

 

 

Product Features
 

Anti-loosening process

We apply anti-loosening glue to all fasteners of the transformer (such as bolts, nuts, etc.) and perform other anti-loosening treatments to avoid displacement of internal components or poor contact.

Multi-layer cylindrical structure

The winding of this oil-immersed transformer adopts a layered cylindrical structure, which can effectively resist short-circuit current impact and avoid winding deformation.

High-quality raw materials

This transformer is stamped from high-quality silicon steel sheets. High-quality silicon steel sheets can effectively reduce core losses and ensure efficient operation of the transformer.

 

Main Technical Parameters

 

 

Rated

Capacity

(kVA)

Voltage

Marks

No-Load

Loss

(W)

On-Load

Loss

(W)

Short

cirait-z

(%)

No-Load

Cur

(%)

Weight(kg)

Size(mm)

Distance

(mm)

V

(kV)

Chng

(%)

V

(kV)

Wain w.t

Oil w.t

Ttl w.t

L·W·H

50

35

±5%

0.4

Yyn0

Or

Dyn11

210

1210/1270

6.5

2.0

230

270

700

1030×850×1460

550×550

100

290

2020/2120

1.8

370

320

950

1080×935×1580

550×550

125

340

2380/2500

1.7

440

350

1090

1100×940×1610

550×550

160

360

2830/2970

1.6

530

380

1120

1120×1035×1630

550×550

200

430

3330/3500

1.5

600

410

1340

1150×1050×1670

660×660

250

510

3960/4160

1.4

690

450

1520

1450×1130×1700

660×660

315

610

4770/5010

1.4

800

490

1730

1885×910×1720

660×660

400

730

5760/6050

1.3

920

540

1960

1950×1010×1820

660×660

500

860

6930/7280

1.2

1060

590

2210

2010×1070×1860

660×660

630

1040

8280

1.1

1460

620

2510

2100×1180×1960

660×660

800

1230

9900

1.0

1520

670

2940

2170×1260×2060

820×820

1000

1440

12150

1.0

1890

990

3910

2200×1690×2120

820×820

1250

1760

14670

0.9

2100

1090

4590

2230×1710×2250

820×820

1600

2120

17550

0.8

2820

1150

5150

235O×2020×2330

820×820

2000

2720

19350

0.7

2950

1200

5360

2600×2120×2350

820×820

2500

3200

20700

0.6

3350

1290

5870

2620×2220×2470

1070×1070

 

Note:
1. The diagonal load loss values ​​in the table below are applicable to products in the Dyn11 connection group.
2. If you need to know the technical parameters, dimensions and weight data of 35kV large-capacity distribution transformers, please contact us.
3. We can provide transformers with various voltage levels, short-circuit impedances and coupling methods according to user requirements.
4. The weight and size data in the table are for reference only.

 

Application Scope

 

 

1. Normal use environment: altitude not exceeding 1000m; temperature range: -25℃--+45℃
2. Special use environment: altitude over 1000m; temperature range: -45℃--+40℃
3. Relative humidity: ≤90℃ (+25℃)
4. Installation location: no corrosive gas, no obvious stains
5. This product is suitable for industrial, agricultural lighting and power transmission

 

 

 

Executive Standards

 

 

GB1094.1~2-1996

GB1094.4-2005

GB1094.3, 5-2003

GB/T6451-2008

 

 

FAQ

 

 

Q: What is the lead time for delivering a 2000 kVA oil-immersed transformer?

A: Normal within 15 days. It depends on detail items and quantity.Please contact us for details.

Q: How to get product quotation?

A: You can contact us anytime through the contact information on the website. You will receive our response within 24 hours.

Q: What after-sales services can I enjoy?

A: The transformer comes with a one-year warranty. Long-term online technical support is provided, along with customer training, and regular updates to maintenance manuals and technical guides.

Q: How long is the average lifespan of a transformer?

A: The lifespan ranges from 20 to 40 years, influenced by factors such as maintenance level, operating environment, and load conditions.

Q: If your factory is a parts processing plant, what transformer capacity is suitable?

A: The selection should be based on the facility size. Small-scale processing workshops can use a 150kVA transformer, while medium-sized manufacturing plants are generally recommended to install 500kVA transformers or higher.

Q: Do you have oil-immersed transformers and dry-type transformers in stock?

A: No, as transformers require customized parameters based on demand, we usually need to design them after receiving an order.

 

1
2

 

 

Hot Tags: 50-2500kva/35kv oil immersed double winding transformer, China 50-2500kva/35kv oil immersed double winding transformer manufacturers, suppliers, factory, Energy Efficiency Oil Immersed Transformer, 500 kva oil filled transformer, 150 kva transformer , 100 kva distribution transformer, 50 2500kVA 10kV Super Low loss Oil Immersed Transformer, Photovoltaic Box Transformer

Send Inquiry