Products
30-2500kVA/10kV Three Phase Oil Immersed Transformer​
video
30-2500kVA/10kV Three Phase Oil Immersed Transformer​

30-2500kVA/10kV Three Phase Oil Immersed Transformer​

S9

● High voltage side voltage: 6kV, 6.3kV, 10kV, 10.5kV, 11kV

● Low voltage Side voltage: 0.4kV

● Tapping Range:  ±2×2.5%, ±5%

● Transformer Vector Group: Yyn0 or Dyn11

● Tap Changer: NLTC or OLTC

● Certification: ISO9001, IEC60076, etc.

Note: More parameters can be customized according to customer requirements.

Payment & Shipping Terms

● Minimum Order Quantity: 1 piece

● Delivery Time: 10 to 20 days

● Packaging Details: wooden case

● Payment Terms: T/T, L/C, PayPal, Alipay/WeChat Pay, Visa

Product Overview

 

 

This three-phase oil-immersed transformer is an energy-saving transformer designed for medium and low voltage power distribution systems. It complies with IEC60076, ISO9001 and other quality standards. This transformer can meet your different power supply needs, such as industrial and mining enterprises, commercial buildings, residential communities and other places.

 

 

Type And Meaning

 

 

1

 

Product Features
 

Three radiator types available

This three-phase oil-immersed transformer offers three radiator options: corrugated, panel-type, and tubular types. You can select the appropriate type based on application requirements.

Customizable High-Protection Enclosure

The transformer enclosure can be configured with an IP55 or higher protection rating, ensuring excellent resistance to moisture, dust, and salt spray for reliable outdoor operation.

stable core structure

The transformer core adopts a stepped three-limb construction. This can effectively reduces no-load loss and operational noise.

Main Technical Parameters

 

 

Rated

Capacity

(kVA)

Voltage

Vector Group

No-Load

Loss

(W)

On-Load

Loss

(W)

Short

cirait-z

(%)

No-Load

Cur

(%)

Weight(kg)

Size(mm)

Distance

(mm)

V

(kV)

Chng

(%)

V

(kV)

Wain w.t

Oil w.t

Ttl w.t

L·W·H

30

6

6.3

10

10.5

11

±5%

Or

±2×2.5

0.4

Yyn0

Or

Dyn11

130

600/630

4.0

2.3

165

60

280

940×555×1000

400×400

50

170

870/910

2.0

200

90

385

1020×630×1100

400×400

63

200

1040/1090

1.9

230

100

420

1040×600×1120

400×400

80

250

1250/1310

1.9

280

115

495

1070×660×1130

400×450

100

290

1500/1580

1.8

310

130

565

1080×730×1170

400×450

125

340

1800/1890

1.7

350

150

640

1100×780×1190

450×550

160

400

2200/2310

1.6

410

165

740

1190×840×1260

550×550

200

480

2600/2730

1.5

490

170

910

1490×770×1270

550×550

250

560

3050/3200

1.4

570

190

990

1570×820×1330

550×550

315

670

3650/3830

1.4

670

230

1220

1720×960×1360

550×550

400

800

4300/4520

1.3

800

250

1430

1720×960×1400

660×660

500

960

5150/5410

1.2

940

290

1670

1800×1010×1460

660×660

630

1200

6200

4.5

1.1

1100

350

1940

2000×1140×1650

660×660

800

1400

7500

1.0

1370

385

2190

2200×1200×1700

820×820

1000

1700

10300

1.0

1520

471

2780

2230×1260×1800

820×820

1250

1950

12000

0.9

1820

520

3340

2310×1300×1900

820×820

1600

2400

14500

0.8

2150

660

3790

2390×1360×1950

820×820

2000

2520

17820

0.8

2310

833

4400

2120×1860×2250

820×820

2500

2970

20700

0.8

2730

900

4940

2150×2000×2300

820×820

 

Note:
1. The load loss values ​​below the diagonal in the table below are for products with a Dyn11 connection group.
2. The minimum capacity of conventionally produced transformers is 30kVA. For lower capacities, please consult us.
3. We can provide transformers with various voltage levels, short-circuit impedances, and coupling methods according to user needs.
4. The weight and dimensions provided in the table are for reference only. For detailed specifications, please contact us.

 

 

 

Application Scope

 

 

1. Normal use environment: altitude not exceeding 1000m; temperature range: -25℃--+45℃

2.  Special environment: altitude above 1000m; temperature range: -45℃--+40℃

3. Relative air humidity: ≤90℃ (+25℃)

4. Installation site: no corrosive air, no obvious stains

5. This oil-immersed transformer is used for lighting and power transmission in industry and agriculture

 

Executive Standards

 

 

GB1094.1~2-1996

GB1094.4-2005

GB1094.3, 5-2003

GB/T6451-2008

 

FAQ

 

 

Q: How long is the delivery time?

A: Normal within 10 days. It depends on detail items and quantity.Please contact us for details.

Q: How to get product quotation?

A: You can contact us anytime through the contact information on the website. You will receive our response within 24 hours.

Q: What after-sales services can I enjoy?

A: The transformer comes with a one-year warranty. Long-term online technical support is provided, along with customer training, and regular updates to maintenance manuals and technical guides.

Q: How long is the average lifespan of a transformer?

A: The lifespan ranges from 20 to 40 years, influenced by factors such as maintenance level, operating environment, and load conditions.

Q: How to determine the parameters of the transformer?

A: We can usually find the parameters in transformer nameplates, drawings, outline drawings, and technical tables.

Q: Do you have oil-immersed transformers and dry-type transformers in stock?

A: No, as transformers require customized parameters based on demand, we usually need to design them after receiving an order.

 

1
2

 

 

Hot Tags: 30-2500kva/10kv three phase oil immersed transformer​, China 30-2500kva/10kv three phase oil immersed transformer​ manufacturers, suppliers, factory, Energy Efficiency Oil Immersed Transformer, 500 kva oil filled transformer, 150 kva transformer , 100 kva distribution transformer, 50 2500kVA 10kV Super Low loss Oil Immersed Transformer, Photovoltaic Box Transformer

Send Inquiry