Product Overview
The SCB11 30–2500kVA/10kV low-loss resin-cast dry-type power transformer is a professionally engineered, high-performance electrical solution built to satisfy the versatile and demanding power distribution requirements of modern industrial, commercial and infrastructure sectors. As a highly efficient three-phase dry-type transformer tailored for 10kV power distribution systems, it integrates ultra-low energy loss, exceptional structural stability and long-term operational safety into one compact design, making it a core piece of power equipment for reliable grid operation and energy-saving transformation.
1. Premium Material & Precision Manufacturing for Zero Defects
This transformer is wound with high-strength oxygen-free copper windings that feature superior electrical conductivity, minimal resistance loss and enhanced mechanical strength. Combined with cutting-edge vacuum casting technology and nano-grade epoxy resin curing technology, the product achieves fully seamless lamination and zero air gaps between winding layers. This industry-leading craftsmanship effectively eliminates insulation weaknesses caused by air bubbles or structural gaps, greatly improving insulation stability, heat dissipation efficiency and impact resistance, while laying a solid foundation for long-term stable operation under heavy loads.
2. Strict Quality Inspection for Ultimate Delivery Safety
Every unit undergoes a full set of authoritative and extreme reliability tests before leaving the factory to guarantee 100% qualified delivery. Key performance tests include partial discharge testing controlled below 5pC, which effectively suppresses insulation aging and electrical faults, as well as extreme temperature cycle testing ranging from -40℃ to 155℃ to verify its adaptability to severe cold, high heat and drastic temperature fluctuations. Such rigorous quality control ensures the transformer maintains outstanding performance stability even in harsh outdoor or complex working environments, with zero hidden dangers in long-term operation.
3. Ultra-Low Loss & High Energy Efficiency
With an optimized electromagnetic design and high-quality core materials, the SCB11 series achieves remarkably low no-load and load loss levels. It significantly reduces unnecessary power consumption during operation, delivers outstanding energy-saving benefits, cuts down long-term operating costs for users, and fully aligns with global trends of green, low-carbon and efficient power utilization.
Technical Features
● Wide capacity range of 30kVA–2500kVA, fully matching diversified 10kV power distribution project demands
● High-purity oxygen-free copper windings for low resistance, low heat generation and high conductivity
● Vacuum casting + nano-grade epoxy resin curing process, realizing interlayer seamless bonding and zero air gaps
● Ultra-low partial discharge level (<5pC) to extend service life and improve operational safety
● Wide operating temperature range (-40℃ to 155℃) with strong resistance to temperature shocks and harsh environments
● Epoxy resin cast, oil-free and flame-retardant structure, free of fire and leakage risks
● Excellent short-circuit withstand capability, moisture resistance and corrosion resistance for high environmental adaptability
● Low maintenance requirement, suitable for unattended power distribution stations and critical power supply nodes
Type And Meaning

Application Scope
1. Installation height: not more than 1000m above sea level;
2. Power supply voltage waveform is approximately sinusoidal;
3. Symmetry of multi-phase power supply voltage: the power supply voltage connected to the multi-phase transformer should be approximately symmetrical.
4. Maximum temperature +40℃;
5. Maximum daily average temperature +30℃;
6. Maximum annual average temperature +20℃;
7. Minimum temperature -25℃ (applicable to indoor transformers).
Executive Standards
|
GB1094.11-2007 |
GB1094.3-2003 |
|
GB/T 10228-2008 |
JB/T10088-2004 |
|
GBT17211-1998 |
JB/T 56009-1998 |
Product Features
High mechanical strength
The high-voltage winding of our dry-type transformer is wound with copper wire, filled with glass fiber felt, and poured with epoxy resin under vacuum, which forms a solid cylindrical whole after curing. The low-voltage winding adopts a foil structure, which enhances the mechanical strength, improves the product's ability to resist sudden short circuits, and the coil is not easy to crack.
Excellent moisture-proof performance
The coils of our three-phase dry-type transformer do not absorb moisture, and the core clamps have a special anti-corrosion protective layer. It can operate stably in 100% relative humidity and other harsh environments, and can be put into operation without pre-drying after shutdown.
Perfect temperature control protection
The dry-type transformers we produce can be equipped with an intelligent signal temperature control system, which can automatically monitor and display the operating temperature of each three-phase winding on the same screen, automatically start and stop the fan, and can also set alarm, trip and other functions to provide reliable protection for the safe operation of the transformer.
Main Technical Parameters
|
Rated Capacity (kVA) |
Voltage |
Vector Group |
No-Load Loss (W) |
120℃ On-Load Loss (W) |
Short cirait-z (%) |
No-Load Cur (%) |
Main Unit W.T (kg) |
Shuck W.T (kg) |
Size(mm) |
Distance (mm) |
|||
|
V (kV) |
Chng (%) |
V (kV) |
L·W·H (Without Protective Cover) |
L·W·H (With Protective Cover) |
|||||||||
|
30 |
6 6.3 10 10.5 11 |
±5 Or 2×2.5 |
0.4 |
Yyn0 Or Dyn11 |
170 |
675 |
4 |
2.4 |
310 |
395 |
670×500×695 |
1050×900×1000 |
350×450 |
|
50 |
240 |
950 |
2.4 |
385 |
430 |
670×500×755 |
1050×900×1050 |
350×450 |
|||||
|
80 |
330 |
1310 |
1.8 |
475 |
535 |
930×600×785 |
1300×1000×1100 |
550×550 |
|||||
|
100 |
350 |
1490 |
1.8 |
590 |
660 |
990×600×066 |
1350×1050×1150 |
550×550 |
|||||
|
125 |
410 |
1760 |
1.6 |
665 |
745 |
1030×600×820 |
1400×1050×1150 |
550×550 |
|||||
|
160 |
480 |
2020 |
1.5 |
750 |
840 |
1040×710×940 |
1400×1100×1200 |
660×660 |
|||||
|
200 |
550 |
2410 |
1.4 |
880 |
985 |
1090×710×960 |
1450×1100×1300 |
660×660 |
|||||
|
250 |
630 |
2620 |
1.4 |
1000 |
1120 |
1110×710×1050 |
1500×1100×1350 |
660×660 |
|||||
|
315 |
770 |
3300 |
1.2 |
1150 |
1325 |
1150×710×1100 |
1550×1100×1450 |
660×660 |
|||||
|
400 |
860 |
3790 |
1.2 |
1410 |
1580 |
1250×710×1205 |
1650×1150×1500 |
660×660 |
|||||
|
500 |
1020 |
4640 |
1.2 |
1575 |
1760 |
1280×870×1290 |
1650×1250×1650 |
820×820 |
|||||
|
630 |
1180 |
5590 |
1.0 |
1950 |
2180 |
1320×870×1380 |
1700×1300×1700 |
820×820 |
|||||
|
630 |
1150 |
5660 |
6 |
1.0 |
1750 |
1960 |
1370×870×1210 |
1750×1300×1650 |
820×820 |
||||
|
800 |
1340 |
6610 |
1.0 |
2030 |
2300 |
1390×870×1360 |
1750×1300×1700 |
820×820 |
|||||
|
1000 |
1560 |
7720 |
1.0 |
2350 |
2650 |
1440×870×1460 |
1800×1300×1800 |
820×820 |
|||||
|
1250 |
1840 |
9200 |
1.0 |
2780 |
3100 |
1520×870×1580 |
1900×1350×1900 |
820×820 |
|||||
|
1600 |
2160 |
11140 |
1.0 |
3250 |
3640 |
1590×870×1620 |
2000×1500×1950 |
820×820 |
|||||
|
2000 |
2690 |
13730 |
0.8 |
3830 |
4310 |
1660×1120×1790 |
2000×1500×2100 |
1070×1070 |
|||||
|
2500 |
3170 |
16300 |
0.8 |
4350 |
4880 |
1720×1120×1910 |
2100×1500×2200 |
1070×1070 |
|||||
Note:
1. The only adjustment for the on-load tap-changing SC(B)9 series transformer is the following: the weight is increased by 100 kg, the on-load tap-changer is arranged on the side (a) or the front (b) of the transformer, and the length is increased by 750 mm.
2. The voltage fluctuation range we can provide is: ±4 × 2.5%.
3. The data in the table is for reference only.
FAQ
Q: How long is the delivery time?
A: Normal within 10 days. It depends on detail items and quantity.Please contact us for details.
Q: How to get product quotation?
A: You can contact us anytime through the contact information on the website. You will receive our response within 24 hours.
Q: What after-sales services can I enjoy?
A: The transformer comes with a one-year warranty. Long-term online technical support is provided, along with customer training, and regular updates to maintenance manuals and technical guides.
Q: How long is the average lifespan of a transformer?
A: The lifespan ranges from 20 to 40 years, influenced by factors such as maintenance level, operating environment, and load conditions.
Q: How to determine the parameters of the transformer?
A: We can usually find the parameters in transformer nameplates, drawings, outline drawings, and technical tables.
Q: Do you have oil-immersed transformers and dry-type transformers in stock?
A: No, as transformers require customized parameters based on demand, we usually need to design them after receiving an order.


Hot Tags: 30-2500kva/10kv low-loss resin casting dry type power transformer, China 30-2500kva/10kv low-loss resin casting dry type power transformer manufacturers, suppliers, factory, Dry Type Amorphous Alloy Distribution Transformer, 63 kva distribution transformer, 1500 kva dry type transformer, cast resin dry type transformer, 50 2500kVA 10kV Dry Type Amorphous Alloy Distribution Transformer, dry type power transformer