30-2500kVA/10kV Low-Loss Resin Casting Dry Type Power Transformer

30-2500kVA/10kV Low-Loss Resin Casting Dry Type Power Transformer

SCB11

● High voltage side voltage: 6kV, 6.3kV, 10kV, 10.5kV, 11kV

● Low voltage Side voltage: 0.4kV

● Tapping Range:  ±2×2.5%, ±5%

● Transformer Vector Group: Yyn0 or Dyn11

● Tap Changer: NLTC or OLTC

● Certification: ISO9001, IEC60076, etc.

Note: More parameters can be customized according to customer requirements.

Payment & Shipping Terms

● Minimum Order Quantity: 1 piece

● Delivery Time: 10 to 20 days

● Packaging Details: wooden case

● Payment Terms: T/T, L/C, PayPal, Alipay/WeChat Pay, Visa

Product Overview

 

 

The SCB11 30–2500kVA/10kV low-loss resin-cast dry-type power transformer is a professionally engineered, high-performance electrical solution built to satisfy the versatile and demanding power distribution requirements of modern industrial, commercial and infrastructure sectors. As a highly efficient three-phase dry-type transformer tailored for 10kV power distribution systems, it integrates ultra-low energy loss, exceptional structural stability and long-term operational safety into one compact design, making it a core piece of power equipment for reliable grid operation and energy-saving transformation.

 

1. Premium Material & Precision Manufacturing for Zero Defects

This transformer is wound with high-strength oxygen-free copper windings that feature superior electrical conductivity, minimal resistance loss and enhanced mechanical strength. Combined with cutting-edge vacuum casting technology and nano-grade epoxy resin curing technology, the product achieves fully seamless lamination and zero air gaps between winding layers. This industry-leading craftsmanship effectively eliminates insulation weaknesses caused by air bubbles or structural gaps, greatly improving insulation stability, heat dissipation efficiency and impact resistance, while laying a solid foundation for long-term stable operation under heavy loads.

 

2. Strict Quality Inspection for Ultimate Delivery Safety

Every unit undergoes a full set of authoritative and extreme reliability tests before leaving the factory to guarantee 100% qualified delivery. Key performance tests include partial discharge testing controlled below 5pC, which effectively suppresses insulation aging and electrical faults, as well as extreme temperature cycle testing ranging from -40℃ to 155℃ to verify its adaptability to severe cold, high heat and drastic temperature fluctuations. Such rigorous quality control ensures the transformer maintains outstanding performance stability even in harsh outdoor or complex working environments, with zero hidden dangers in long-term operation.

 

3. Ultra-Low Loss & High Energy Efficiency

With an optimized electromagnetic design and high-quality core materials, the SCB11 series achieves remarkably low no-load and load loss levels. It significantly reduces unnecessary power consumption during operation, delivers outstanding energy-saving benefits, cuts down long-term operating costs for users, and fully aligns with global trends of green, low-carbon and efficient power utilization.

 

Technical Features

● Wide capacity range of 30kVA–2500kVA, fully matching diversified 10kV power distribution project demands

● High-purity oxygen-free copper windings for low resistance, low heat generation and high conductivity

● Vacuum casting + nano-grade epoxy resin curing process, realizing interlayer seamless bonding and zero air gaps

● Ultra-low partial discharge level (<5pC) to extend service life and improve operational safety

● Wide operating temperature range (-40℃ to 155℃) with strong resistance to temperature shocks and harsh environments

● Epoxy resin cast, oil-free and flame-retardant structure, free of fire and leakage risks

● Excellent short-circuit withstand capability, moisture resistance and corrosion resistance for high environmental adaptability

● Low maintenance requirement, suitable for unattended power distribution stations and critical power supply nodes

 

 

Type And Meaning

 

 

1

 

 

 

Application Scope

 

 

1. Installation height: not more than 1000m above sea level;

2. Power supply voltage waveform is approximately sinusoidal;

3. Symmetry of multi-phase power supply voltage: the power supply voltage connected to the multi-phase transformer should be approximately symmetrical.

4. Maximum temperature +40℃;

5. Maximum daily average temperature +30℃;

6. Maximum annual average temperature +20℃;

7. Minimum temperature -25℃ (applicable to indoor transformers).

 

 

 

Executive Standards

 

 

GB1094.11-2007

GB1094.3-2003

GB/T 10228-2008

JB/T10088-2004

GBT17211-1998

JB/T 56009-1998

 

 

 

Product Features

 

 

High mechanical strength

The high-voltage winding of our dry-type transformer is wound with copper wire, filled with glass fiber felt, and poured with epoxy resin under vacuum, which forms a solid cylindrical whole after curing. The low-voltage winding adopts a foil structure, which enhances the mechanical strength, improves the product's ability to resist sudden short circuits, and the coil is not easy to crack.

Excellent moisture-proof performance

The coils of our three-phase dry-type transformer do not absorb moisture, and the core clamps have a special anti-corrosion protective layer. It can operate stably in 100% relative humidity and other harsh environments, and can be put into operation without pre-drying after shutdown.

Perfect temperature control protection

The dry-type transformers we produce can be equipped with an intelligent signal temperature control system, which can automatically monitor and display the operating temperature of each three-phase winding on the same screen, automatically start and stop the fan, and can also set alarm, trip and other functions to provide reliable protection for the safe operation of the transformer.

 

 

 

 

 

Main Technical Parameters

 

 

Rated

Capacity

(kVA)

Voltage

Vector

Group

No-Load

Loss

(W)

120℃

On-Load

Loss

(W)

Short

cirait-z

(%)

No-Load

Cur

(%)

Main Unit

W.T

(kg)

Shuck

W.T

(kg)

Size(mm)

Distance

(mm)

V

(kV)

Chng

(%)

V

(kV)

L·W·H

(Without Protective Cover)

L·W·H

(With Protective Cover)

30

6

6.3

10

10.5

11

±5

Or

2×2.5

0.4

Yyn0

Or

Dyn11

170

675

4

2.4

310

395

670×500×695

1050×900×1000

350×450

50

240

950

2.4

385

430

670×500×755

1050×900×1050

350×450

80

330

1310

1.8

475

535

930×600×785

1300×1000×1100

550×550

100

350

1490

1.8

590

660

990×600×066

1350×1050×1150

550×550

125

410

1760

1.6

665

745

1030×600×820

1400×1050×1150

550×550

160

480

2020

1.5

750

840

1040×710×940

1400×1100×1200

660×660

200

550

2410

1.4

880

985

1090×710×960

1450×1100×1300

660×660

250

630

2620

1.4

1000

1120

1110×710×1050

1500×1100×1350

660×660

315

770

3300

1.2

1150

1325

1150×710×1100

1550×1100×1450

660×660

400

860

3790

1.2

1410

1580

1250×710×1205

1650×1150×1500

660×660

500

1020

4640

1.2

1575

1760

1280×870×1290

1650×1250×1650

820×820

630

1180

5590

1.0

1950

2180

1320×870×1380

1700×1300×1700

820×820

630

1150

5660

6

1.0

1750

1960

1370×870×1210

1750×1300×1650

820×820

800

1340

6610

1.0

2030

2300

1390×870×1360

1750×1300×1700

820×820

1000

1560

7720

1.0

2350

2650

1440×870×1460

1800×1300×1800

820×820

1250

1840

9200

1.0

2780

3100

1520×870×1580

1900×1350×1900

820×820

1600

2160

11140

1.0

3250

3640

1590×870×1620

2000×1500×1950

820×820

2000

2690

13730

0.8

3830

4310

1660×1120×1790

2000×1500×2100

1070×1070

2500

3170

16300

0.8

4350

4880

1720×1120×1910

2100×1500×2200

1070×1070

 

Note:

1. The only adjustment for the on-load tap-changing SC(B)9 series transformer is the following: the weight is increased by 100 kg, the on-load tap-changer is arranged on the side (a) or the front (b) of the transformer, and the length is increased by 750 mm.

2. The voltage fluctuation range we can provide is: ±4 × 2.5%.

3. The data in the table is for reference only.

 

 

 

FAQ

 

 

Q: How long is the delivery time?

A: Normal within 10 days. It depends on detail items and quantity.Please contact us for details.

Q: How to get product quotation?

A: You can contact us anytime through the contact information on the website. You will receive our response within 24 hours.

Q: What after-sales services can I enjoy?

A: The transformer comes with a one-year warranty. Long-term online technical support is provided, along with customer training, and regular updates to maintenance manuals and technical guides.

Q: How long is the average lifespan of a transformer?

A: The lifespan ranges from 20 to 40 years, influenced by factors such as maintenance level, operating environment, and load conditions.

Q: How to determine the parameters of the transformer?

A: We can usually find the parameters in transformer nameplates, drawings, outline drawings, and technical tables.

Q: Do you have oil-immersed transformers and dry-type transformers in stock?

A: No, as transformers require customized parameters based on demand, we usually need to design them after receiving an order.

 

1
2

 

Hot Tags: 30-2500kva/10kv low-loss resin casting dry type power transformer, China 30-2500kva/10kv low-loss resin casting dry type power transformer manufacturers, suppliers, factory, Dry Type Amorphous Alloy Distribution Transformer, 63 kva distribution transformer, 1500 kva dry type transformer, cast resin dry type transformer, 50 2500kVA 10kV Dry Type Amorphous Alloy Distribution Transformer, dry type power transformer