Product Overview
If you prioritize exceptional energy efficiency, stable power delivery and long-term operational safety for your power distribution system, the SCB13 series 50-2500kVA / 10kV dry-type power transformer stands as the optimal solution for modern industrial, commercial and infrastructure power networks. As a high-performance dry-type transformer fully complying with GB 20052-2020 Level 2, the latest national energy efficiency standard, this product is engineered to satisfy the strict demands of diverse critical applications - including industrial manufacturing, commercial complexes, public infrastructure and other key power sectors. Featuring an oil-free, eco-friendly design, it eliminates the risks of oil leakage, fire and pollution, perfectly addressing the industry's urgent needs for safe, low-loss, maintenance-friendly and environmentally responsible power conversion.

Class-Leading Energy Efficiency for Cost Reduction
The SCB13 series achieves remarkable improvements in energy performance over traditional models. Compared with the mainstream SCB11 series, its no-load loss is reduced by 20%, while the load loss is further optimized by 12%. These substantial reductions in power loss directly translate to lower daily energy consumption, significant cuts in long-term operating electricity costs and a lighter carbon footprint. For end-users, this means not only full compliance with national energy regulations but also tangible economic benefits throughout the transformer's service life.
Outstanding Structural Stability & Mechanical Strength
Built with a sophisticated multi-layer dense winding structure and processed via high-temperature and high-pressure curing technology, the transformer delivers exceptional mechanical robustness. The production process strictly controls the thickness tolerance of the insulation layer within ≤ 0.1mm, ensuring uniform insulation distribution, enhanced resistance to short-circuit currents, voltage shocks and long-term cyclic loads. This premium structural design greatly reduces the probability of failure and ensures uninterrupted power supply even in harsh operating environments.
Ultra-Low Partial Discharge for High Operational Safety
The product maintains an ultra-low partial discharge level of below 5pC, far exceeding industry average standards. This critical performance indicator effectively suppresses insulation aging and electrical corrosion, minimizing the risk of insulation breakdown and internal faults. Combined with its fire-retardant, non-polluting dry-type structure, it provides a high-safety power solution for densely populated areas, indoor power stations, commercial centers and other safety-sensitive scenarios.
Technical Features
● Adopts epoxy resin casting dry-type structure, oil-free, flame-retardant and pollution-free, with excellent environmental adaptability.
● Multi-layer dense winding design with precision-controlled insulation layer thickness tolerance ≤ 0.1mm for superior insulation performance.
● High-temperature & high-pressure curing process reinforces winding integrity, delivering strong short-circuit resistance and mechanical stability.
● Ultra-low partial discharge level (< 5pC) to extend service life and ensure safe, stable long-term operation.
● Optimized electromagnetic design to minimize energy loss, achieving 20% lower no-load loss and 12% optimized load loss vs. SCB11 series.
● Maintenance-free operation, suitable for indoor installation and high-safety, high-reliability power distribution scenarios.
Type And Meaning

Application Scope
1. Installation height: not more than 1000m above sea level;
2. Power supply voltage waveform is approximately sinusoidal;
3. Symmetry of multi-phase power supply voltage: the power supply voltage connected to the multi-phase transformer should be approximately symmetrical.
4. Maximum temperature +40℃;
5. Maximum daily average temperature +30℃;
6. Maximum annual average temperature +20℃;
7. Minimum temperature -25℃ (applicable to indoor transformers).
Product Features
Superior core performance
Our dry-type transformers use high-permeability high-quality grain-oriented cold-rolled silicon steel sheets. This material has high magnetic permeability and can effectively reduce hysteresis loss and eddy current loss. At the same time, the 45° fully inclined step seam lamination process makes the magnetic circuit smoother and reduces magnetic resistance.
Good moisture-proof performance
The overall moisture-proof performance of the transformer is excellent. The winding surface may be sprayed with three-conformal paint. It can still operate normally under 100% humidity. It can be put into operation without pre-drying after shutdown. It can adapt to humid environments such as tunnels, underground power stations and other places.
Reliable electrical performance
The high-voltage winding of this dry-type transformer adopts segmented and layered design, which reduces the voltage between winding layers. It also adopts vacuum casting of epoxy resin with filler, which reduces the amount of partial discharge inside the winding and improves the electrical performance of the coil.
Main Technical Parameters
|
Rated |
Voltage combination |
Vector |
No-load |
Load loss(W) |
No-load |
Impedance |
Sound |
Overall dimension |
Total |
||||
|
High |
tap |
Low |
|||||||||||
|
130℃(B) |
155℃(F) |
180℃(H) |
|||||||||||
|
100℃ |
120℃ |
145℃ |
|||||||||||
|
30 |
6.3 |
±2×2.5 |
0.4 |
Dyn11 |
135 |
605 |
640 |
685 |
0.6 |
4.0 |
57 |
955×1100×840 |
360 |
|
50 |
195 |
845 |
900 |
965 |
0.6 |
970×1120×860 |
420 |
||||||
|
80 |
265 |
1160 |
1240 |
1330 |
0.6 |
58 |
1015×1150×925 |
460 |
|||||
|
100 |
290 |
1330 |
1415 |
1520 |
0.6 |
1060×1210×960 |
560 |
||||||
|
125 |
340 |
1565 |
1665 |
1780 |
0.6 |
59 |
1075×1230×1000 |
630 |
|||||
|
160 |
385 |
1800 |
1915 |
2050 |
0.6 |
1105×1260×1045 |
770 |
||||||
|
200 |
445 |
2135 |
2275 |
2440 |
0.5 |
60 |
1120×1270×1105 |
875 |
|||||
|
250 |
515 |
2330 |
2485 |
2665 |
0.5 |
1195×1350×1125 |
1055 |
||||||
|
315 |
635 |
2945 |
3125 |
3355 |
0.5 |
62 |
1225×1380×1140 |
1190 |
|||||
|
400 |
705 |
3375 |
3590 |
3850 |
0.4 |
1315×1470×1190 |
1500 |
||||||
|
500 |
835 |
4130 |
4390 |
4705 |
0.4 |
63 |
1345×1500×1265 |
1700 |
|||||
|
630 |
965 |
4975 |
5290 |
5660 |
0.4 |
63 |
1555×1700×1175 |
1985 |
|||||
|
630 |
935 |
5050 |
5365 |
5760 |
0.3 |
6.0 |
63 |
1555×1700×1175 |
1985 |
||||
|
800 |
1090 |
5895 |
6265 |
6715 |
0.3 |
65 |
1600×1750×1220 |
2360 |
|||||
|
1000 |
1275 |
6885 |
7315 |
7885 |
0.3 |
1660×1810×1285 |
2775 |
||||||
|
1250 |
1505 |
8190 |
8720 |
9335 |
0.25 |
67 |
1720×1870×1350 |
3310 |
|||||
|
1600 |
1765 |
9945 |
10555 |
11320 |
0.25 |
1780×1930×1405 |
3940 |
||||||
|
2000 |
2195 |
12240 |
13005 |
14005 |
0.2 |
69 |
1840×1990×1475 |
4595 |
|||||
|
2500 |
2590 |
14535 |
15455 |
16605 |
0.2 |
1900×2050×1565 |
5495 |
||||||
|
1600 |
1760 |
11000 |
11600 |
12500 |
0.25 |
8.0 |
67 |
1780×1930×1405 |
3940 |
||||
|
2000 |
2190 |
13500 |
14300 |
15400 |
0.2 |
69 |
1840×1990×1475 |
4595 |
|||||
|
2500 |
2590 |
15900 |
17000 |
18200 |
0.2 |
1900×2050×1565 |
5495 |
||||||
1. If you need to know the technical parameters, dimensions and weight data of 10kV large-capacity distribution transformers, please contact us.
2. Transformers of various voltage levels, short-circuit impedances and coupling modes can be provided according to user needs.
3. The weight and dimension data in the table are for reference only and are subject to change without prior notice.
FAQ
Q: How long is the delivery time?
A: Normal within 10 days. It depends on detail items and quantity.Please contact us for details.
Q: How to get product quotation?
A: You can contact us anytime through the contact information on the website. You will receive our response within 24 hours.
Q: What after-sales services can I enjoy?
A: The transformer comes with a one-year warranty. Long-term online technical support is provided, along with customer training, and regular updates to maintenance manuals and technical guides.
Q: How long is the average lifespan of a transformer?
A: The lifespan ranges from 20 to 40 years, influenced by factors such as maintenance level, operating environment, and load conditions.
Q: How to determine the parameters of the transformer?
A: We can usually find the parameters in transformer nameplates, drawings, outline drawings, and technical tables.
Q: Do you have oil-immersed transformers and dry-type transformers in stock?
A: No, as transformers require customized parameters based on demand, we usually need to design them after receiving an order.
Hot Tags: 50-2500kva/10kv super low-loss dry type power transformer, China 50-2500kva/10kv super low-loss dry type power transformer manufacturers, suppliers, factory, Dry Type Amorphous Alloy Distribution Transformer, 63 kva distribution transformer, 1500 kva dry type transformer, cast resin dry type transformer, 50 2500kVA 10kV Dry Type Amorphous Alloy Distribution Transformer, dry type power transformer